Evaluating Electricity Procurement Options for Federal Agencies

This page connects federal agencies to Federal Energy Management Program (FEMP) resources and information regarding strategies to procure electricity in line with federal requirements. Additionally, the steps outlined below represent a comprehensive approach to planning and procurement of such resources.

Existing federal requirements relevant to electricity procurement include:

Energy Policy Act of 2005 (EPAct 2005)—Requires federal agencies to source at least 7.5% of their electricity from renewable sources and promotes energy efficiency, alternative fuel vehicles, and advanced energy technologies.

EPAct 2005 defines the following sources as renewable: 

  • Solar
  • Wind
  • Geothermal
  • Hydrokinetic
  • Biomass
  • Landfill gas
  • Municipal solid waste
  • New hydropower or hydropower that improves efficiency or provides additional capacity at existing plants. 

Please refer to Federal Renewable Energy Use Requirement for additional information.

Energy Independence and Security Act of 2007 (EISA 2007)—Established guidelines and requirements for energy intensity reduction, building performance standards, and energy benchmarking. 

Energy Act of 2020—Encourages deployment of thermal energy generation, nuclear energy, storage, renewable energy, and carbon capture, utilization, and sequestration technologies (e.g., sec 1310(a)(3)-(5))  and the integration of innovative clean energy technologies.

Assess, strategize and implement. Understand site utility markets and distributed energy resources. Identify feasible, impactful pathways to increase distributed energy resources. Execute procurement strategies for distributed energy resources.

Assess

Assess the options available to your site based on the utility regulatory environment in which it is located. Available options will differ depending upon the market structure.

  • Have a question?

    Visit the FEMP Assistance Request Portal for general questions.

    For questions in retail electric choice markets:

    Utility regulatory markets in the United States are typically determined at the state level and generally fall into one of two types: (1) vertically integrated markets (sometimes referred to as "regulated markets"), and (2) retail electric choice markets (sometimes referred to as "deregulated markets" or "competitive markets").

    The procurement options for these market types differ and will be discussed in detail under the Strategize section, below. Figures 1 and 2 illustrate the differences between the market structures.

    In vertically integrated markets, the serving utility is responsible for generation, transmission, and distribution of electricity. Customers receive all services including commodity electricity from their serving utility. A site's serving utility is determined by its geographic location.

    A visual representation of a vertically integrated market overview.

    Figure 1. Vertically integrated market overview.

    Exception: Electric cooperatives and municipalities are generally structured as vertically integrated providers.

    In retail electric choice markets, customers can choose their electricity supplier and work with GSA or DLA Energy for their commodity electricity purchases, which will be aggregated with other federal loads.

    The following states have either complete or partial retail electric choice: California*, Connecticut, Delaware, Illinois*, Maine, Maryland, Massachusetts, Michigan, New Hampshire, New Jersey, New York, Ohio, Oregon, Pennsylvania, Rhode Island, Texas*, Virginia*, and Washington, D.C.

    *Electric choice may not be available in all parts of the state or for all customers.

    A representation of retail electric choice markets.

    Figure 2. Retail electric choice market overview.

    ACTION: Categorize sites based on the regulatory market in which they are located (e.g., retail electric choice, vertically integrated).

    Because individual states regulate electric utility purchases and sales within their borders, the rules and options regarding the purchase of electricity will vary depending upon a site’s geographic location.

  • The electricity supply and demand must be balanced at all times for the electric grid to function properly and avoid blackouts. Within the United States, 66 balancing authorities play the key role of maintaining balance between electricity supply and demand within specific geographic regions. Some of these balancing authorities are individual utilities while others are larger regional transmission organizations that balance loads in areas that encompass multiple states.

    As facilities consider strategies for increasing off-site procurement of energy sources in line with federal requirements or resilience goals, they may wish to prioritize generators that are relatively local to the facility and can deliver to the balancing area where the facility is located.

    Satellite view of the United States at night.
    Balancing Authority Lookup Tool

    Identify the balancing area of your facility by entering its zip code.

  • Leverage existing information on identified energy conservation measures (ECMs) to project estimated reductions in load. Consider deep energy retrofits and projects funded through performance contracting options such as energy saving performance contracts (ESPCs) and utility energy service contracts (UESCs).

  • Reminder: Fleet electrification, data centers, and supercomputers will increase your load.

    Project future electricity load for each site. This is particularly important when there are plans for a significant increase or decrease in annual electricity consumption due to changes in facility usage or mission, for example.

    For sites planning to increase their electric vehicle fleet, the FEMP Utility Program Navigator can help federal agencies locate incentives offered by their utilities.

Strategize

Identify feasible, impactful pathways to procure generation that meet energy goals and statutory requirements and reduce costs.

  • On-Site Projects

    Reminder: Consider interconnection requirements early in the project development process and refer to the Distributed Energy Interconnection Checklist.

    Inventory

    ACTION: Take an inventory of available information related to on-site energy generation.

    • Do your sites have available real property that could be used to site energy generation or storage (e.g., rooftop, parking structures, adjoining land)?
    • Agencies seeking to develop government-owned on-site energy projects: 
    • Agencies seeking to develop third-party owned on-site energy projects:
      • Would your Agency consider hosting utility- or privately-owned energy generation on your land? FEMP is available for related questions or requests for help at our Technical Assistance portal.
         

    FEMP Resources

    Refer to the following FEMP resources for more information and technical assistance.

    Performance Contracting Options

    Energy Savings Performance Contracts (ESPCs), ESPC ENABLE Projects, and Utility Energy Service Contracts (UESCs), are collectively known as "performance contracts." Performance contracts are a useful strategy for installing energy conservation measures that increase energy and water efficiency as well as installing energy projects at federal sites without upfront capital funding.

    The Energy Act of 2020 amended 42 U.S.C. § 8253(f)(4) to include a new requirement for federal agencies to implement all life-cycle cost-effective energy- or water-saving measures identified in a federal agency's evaluation of a federal facility subject to the requirements of 42 U.S.C. 8253(f) ("covered facility") not later than two years after the completion date of the evaluation.

    Further, at least 50% of the project implementation must be accomplished through performance contracts.

    Refer to the following FEMP resources for more information:

    • Federal On-site Distributed Energy Project Financing Options: Description of distributed energy project financing options
    • ESPC, including ESPC ENABLE: Details performance contracting mechanism to procure energy savings and facility improvements with no upfront capital costs through a partnership
    • ESPC Energy Sales Agreement: Details use of the multiyear ESPC authority to implement distributed energy projects on federal buildings or land between an agency and an energy service company
    • UESC: Details the limited source acquisition between a federal agency and serving utility for energy management services.
  • Identify how your site or sites take electric service. Part of a comprehensive plan to achieve agency goals is an understanding of how contract expirations provide opportunities to move towards consumption that provides resiliency and cost savings benefits while meeting federal requirements.

    Vertically Integrated Markets

    Agencies should understand the rate schedule, tariff, or separate contract under which they take electric utility service. Agencies will most commonly take electric service via a Task Order issued by the Agency under the appropriate GSA Areawide Contract (AWC). Pursuant to Federal Acquisition Regulation (FAR) Part 41.204(c), using the GSA AWC is required unless determined by the Agency Head Contracting Authority that its use is not advantageous to the Government.

    Where no GSA AWC exists, sites will have negotiated separate contracts or interagency agreements in accordance with FAR Part 41.205; FAR Part 41.206. GSA's Utility Areawide Guide provides information for procuring utility services through AWCs.

    ACTION: Take note of the following in vertically integrated markets:

    • Sites with expiring electricity contracts
    • Sites served by a utility with a GSA AWC that are not taking service via a task order under the AWC
    • Sites taking electric service under a separate contract.
    Electric transmissions lines are dusk

    Utility Rate Options

    Evaluate your utility rate options in vertically integrated markets.

    Retail Electric Choice Markets

    DLA Energy and GSA serve as centralized electricity procurement agents for federal customers in retail electric choice markets. Agencies should identify if DLA Energy or GSA currently procures commodity power for the site. Where sites are in retail choice markets, but do not procure electricity through DLA Energy or GSA, agencies should contact DLA Energy or GSA for information on how to participate in aggregated federal procurements.

    ACTION: Take note of the following in retail electric choice markets:

    • Sites with expiring electricity contracts
    • Sites that are not aggregating their load through DLA Energy and/or GSA
    • Sites in retail electric choice markets that don’t competitively procure their electricity supply (meaning their electricity is supplied by their distribution utility).

    Please refer to the FEMP Utility Program Navigator for more information about each option, including an overview, information about the applicable market type, cost savings potential, contract length, choice of generating technology, and renewable energy certificates (RECs).

    An electricity substation.
    FEMP Utility Program Navigator

    FEMP's Utility Program Navigator helps agencies navigate the complexities of utility offerings by simplifying information on programs that may contribute to meeting their energy goals and statutory requirements. Visit the Program Navigator for a list of energy purchasing programs offered by vertically integrated utilities.

  • Off-site energy options are market dependent, though some options are available in both vertically integrated and retail electric choice markets.

Implement

Implement energy efficiency measures, off-site procurement, and on-site generation and/or energy storage projects.

  • Increase on-site energy generation where projects are cost-effective and scalable, and meet other strategic objectives. On-site projects may provide additional opportunities for energy efficiency, resilience, or to electrify other energy-intensive site loads, which may help agencies meet other statutory goals.

  • Examine utility offerings to determine if there are programs available that are best suited to meet your goals; switch to these programs if available to the site's customer class.

  • Ensure all commodity requirements are coordinated with GSA or DLA Energy for inclusion in their regional procurements.

  • Detail annual electricity use through the Annual Energy Management Data Report workbook. Follow FEMP Annual Energy Reporting Guidance.

  • On an annual basis, assess the achievement of agency annual targets and the success of various procurement strategies and adjust as needed to stay on track.

Need Assistance?

U.S. Department of Energy's Federal Energy Managemen Program logo

Need energy management guidance? Can't find a document or tool? FEMP can help. Ask FEMP a question.