Federal Building Energy Efficiency Rules and Requirements

Notification of Compliance Stay: Clean Energy for New Federal Buildings and Major Renovations of Federal Buildings

The Department of Energy (DOE) is reviewing its recent guidance related to the implementation of newly adopted provisions regarding Clean Energy for New Federal Buildings and Major Renovations of Federal Buildings (CER). While DOE reviews the CER implementation guidance, DOE is staying the compliance date for the newly adopted provisions in the Code of Federal Regulations (CFR). 

As of September 2, 2026, the compliance date for 10 CFR part 433, subpart B, and 10 CFR part 435, subpart B, published at 89 FR 35384 (May 1, 2024), and stayed on May 5, 2025 (90 FR 18911) and again on April 20, 2026 (91 FR 20868), is further stayed until March 1, 2027.  Read more details in the Federal Register.

Questions? Send an email to Clean Energy Rule Info.

The Federal Energy Management Program (FEMP) plays a key role in helping agencies understand and meet the federal building energy efficiency standards for agencies' new construction and major renovation projects. These standards include base building efficiency as defined in the CFR by subpart A of 10 CFR 433 and 10 CFR 435, commonly referred to as the "residential" and "commercial" rules, respectively. This also includes the Clean Energy Rule for qualifying projects as defined by subpart B of 10 CFR 433 and 10 CFR 435. The Clean Energy Rule supplements both the base commercial and residential rules, transitioning new buildings and major renovations away from on-site fossil fuel derived energy consumption.

Federal Building Energy Efficiency Standards

Every new federal building must be designed to meet the energy efficiency standards set forth in either 10 CFR 433 or 10 CFR 435.

New Federal Commercial and Multi-Family High-Rise Residential BuildingsNew Federal Low-Rise (Less than Three Stories) Residential Buildings
10 CFR 43310 CFR 435

Legislative Mandate

Per Section 305 of the Energy Conservation and Production Act (ECPA), as amended, the U.S. Department of Energy (DOE) is required to determine whether energy efficiency standards for new federal buildings should be updated to reflect revisions to voluntary industry standards (ASHRAE 90.1 for commercial and multi-family high-rise residential buildings, and the International Energy Conservation Code (IECC) for low-rise residential buildings). Section 305 of ECPA additionally requires that federal buildings be designed to achieve energy consumption levels that are at least 30% beyond the codified federal standards, where life cycle cost-effective. These requirements are detailed in 10 CFR 433 (Commercial Rule) and 10 CFR 435 (Residential Rule). Further, Section 109 of the Energy Policy Act of 2005, 42 USC 6834 directed DOE to establish revised federal building energy efficiency performance standards.

Commercial Rule

10 CFR 433 Energy Efficiency Standards for the Design and Construction of New Federal Commercial and Multi-Family High-Rise Residential Buildings

The current version of Standard 90.1 required for federal buildings is Standard 90.1-2019.

Formal Rulemaking Docket: EERE-2022-BT-STD-0012

Residential Rule

10 CFR 435 Energy Efficiency Standards for the Design and Construction of New Federal Low-Rise Residential Buildings

The current version of IECC required for federal buildings is IECC 2021.

Formal Rulemaking Docket: EERE-2022-BT-STD-0013

Federal Clean Energy Rule

Certain federal new construction and major renovations must reduce or eliminate on-site consumption of fossil fuels, in addition to meeting the baseline energy efficiency requirements.

Read the final Clean Energy Rule and the Technical Support Document.

Legislative Mandate

Section 433 of Energy Independence and Security Act (EISA) 2007 directs DOE to establish, by rule, revised federal building energy efficiency performance standards for new buildings and major renovations such that certain federal buildings shall be designed to reduce on-site fossil fuel-generated energy consumption, as compared to a similar building in Fiscal Year (FY) 2003:

  • By 90% for new construction or major renovation in FY 2025–FY 2029.
  • By 100% for new construction or major renovation in FY 2030 or later.

This rule applies to new construction and major renovations that exceed certain cost thresholds:

  • For federally owned public buildings (as defined in statute), the threshold is approximately $3.6 million in 2024 dollars.
  • For federally owned non-public federal buildings, the threshold is approximately $3.8 million in 2024 dollars.
  • For leased federal buildings (both public and non-public buildings), the threshold is approximately $1.8 million in 2024 dollars.

The Clean Energy Rule focuses on on-site combustion of fossil fuels only (scope 1 emissions):

  • Applies to fossil fuel use in building operational end-uses only.
  • Does not allow renewable electricity to offset on-site fossil fuel use.
  • Excludes industrial and manufacturing process loads.

Implementation Guidance and Petition Process

Notification of Compliance Stay: Clean Energy for New Federal Buildings and Major Renovations of Federal Buildings

The Department of Energy (DOE) is reviewing its recent guidance related to the implementation of newly adopted provisions regarding Clean Energy for New Federal Buildings and Major Renovations of Federal Buildings (CER). While DOE reviews the CER implementation guidance, DOE is staying the compliance date for the newly adopted provisions in the Code of Federal Regulations (CFR). 

As of April 20, 2026, the compliance date for 10 CFR part 433, subpart B, and 10CFR part 435, subpart B, published at 89 FR 35384 (May 1, 2024), and stayed at 90FR 18911 (May 5, 2025), is further stayed until September 1, 2026. Read more details in the Federal Register.

Questions? Send an email to Clean Energy Rule Info.

This was last updated .