This task encompasses preparation of an aqueous chemical simulant of a Hanford WTP internal recycle waste stream and demonstration of evaporating i…
Office of NEPA Policy and Compliance
May 29, 2019This task encompasses preparation of an aqueous chemical simulant of a Hanford WTP internal recycle waste stream and demonstration of evaporating it in a lab-scale vacuum evaporator to measure partitioning of species between the bottoms and the condensate. Of particular interest is the behavior of iodine. A batch of the simulant will be prepared, typically 3-5 L of solution. Additional batches may be produced (2-3). The batch will be subsampled and analyzed. A vacuum evaporator apparatus will be assembled. The simulant will then be processed through the evaporator. Samples of the liquids collected during the experiment will be submitted to AD for analysis.