Computer Server Selection for Energy Efficiency and Decarbonization in Data Centers

to

A data center houses computer servers, storage, and networking equipment as well as critical support infrastructure such as cooling and electrical systems. These facilities are critical to the mission of many types of organizations, and data center operators are challenged to deliver reliable services, operate efficiently, and ensure resiliency and flexibility. The selection of computer servers can have a profound impact on overall energy efficiency and decarbonization in data centers. This webinar focuses on air-cooled computer server selection guidelines. Air-cooled computer servers generally use more energy than all other information technology (IT) equipment combined.

This webinar also covers the purchase of computer servers that meet strict performance criteria for data centers to operate more efficiently and meet specific federal requirements. Four key industry documents (ASHRAE Thermal Guidelines, Energy Star for Computer Servers, EPEAT, and Standard NSF/ANSI 426-2019) are reviewed to provide a clear understanding of each document's purpose and illustrate ways the individual documents complement one another. This webinar is presented by the Federal Energy Management Program (FEMP) sponsored Center of Expertise for Energy Efficiency in Data Centers at the Lawrence Berkeley National Laboratory.

Instructors

Magnus Herrlin, Principal Scientific Engineering Associate in the High Tech and Industrial Systems Group, Lawrence Berkeley National Laboratory  

Magnus Herrlin is the president of ANCIS Inc. and has been the program lead for the U.S. Department of Energy's (DOE) Data Center Energy Practitioner (DCEP) training program since 2009. The objective of this certificate program is to raise the standards of those involved in energy assessments of data centers. ANCIS develops advanced indoor environmental and energy solutions for facilities in general and for mission-critical facilities in particular. Over a 30-year career, Magnus has developed energy modeling tools and modeled building energy in commercial and residential structures. He has published or contributed to many papers, reports, and standards chiefly concerning thermal management, energy management, mechanical system design and operation, and IT equipment reliability for data centers and telecom central offices.

Jefferey Murrell, Program Manager for the Federal Energy-Intense Facilities, FEMP  

Jefferey Murrell is the program manager for the Federal Energy-Intense Facilities (EIF) program in FEMP and is a licensed professional engineer. He also serves as a program manager for the Federal Metering and Federal Energy Management and Information System (EMIS) programs. He currently supports the Federal Healthy Building Toolkit and Federal Energy Efficient Product Procurement programs. Jeff graduated from Vanderbilt University with a B.S. in general engineering and graduated from Columbia Southern University with a master's in public administration. He is currently matriculating at California Southern University in the Doctorate in Business Administration program, with a focus on energy resiliency and EMIS development/planning.

Ian Hoffman, Senior Scientific Engineering Associate, LBNL

Ian Hoffman is a with the LBNL Center of Expertise for Energy Efficiency in Data Centers and other teams in the Building and Industrial Applications department. His work focuses on efficiency and resilience in data centers, individual and societal behavior on energy and efficiency, and utility customer-funded energy efficiency programs.

Learning Objectives

Upon completion of this course, attendees will be able to:

  • Recognize that the selection of servers can have a significant effect on overall energy efficiency and decarbonization in data centers.
  • Identify four key industry documents that help data centers to operate more energy efficient by purchasing servers that meet certain performance criteria.
  • Identify what each one of the key industry documents covers.
  • Recognize how the documents complement one another.