Includes Pre-March 2011 Type A Reports
For Additional Information Contact:
Jason Brustad, Program Manager
On April 19, 1999, a Special Agent had finished his 1-mile run on a treadmill, walked out of the building and suffered an acute myocardial infarction.
On July 28, 1998, an unexpected activation of the high pressure carbon dioxide fire suppression system occurred in Building 648, Test Reactor Area.
On June 25, 1997, a contract brush-cutting inspector/monitor was fatally injured in a tree-falling accident within a BPA transmission-line corridor.
On June 20, 1997, at BNL, a construction laborer was accidentally run over by a wheel loader as it was backing during a soil grading operation.
On April 25, 1997, a lineman for Great Southwestern was fatally electrocuted when he came in direct contact with a deenergized 230-kilovolt power line
On February 13, 1997, a welder using a cutting torch was fatally burned when his anti-contamination coveralls caught fire.
On August 13, 1996, a Central Facilities Area electrician was injured while working in an enclosure that contained components energized by 2400 VAC.
On July 11, 1996, an electrical shock accident at Los Alamos National Laboratory that resulted in injury to a student employee.
On January 17, 1996, an electrical accident with injury at the LANL, resulted from failures of DOE contractor, and subcontractor management.
On February 20, 1996, at the TSA-RE, a subcontractor project engineer, employed by Caddell, fell approximately 17 feet from a temporary platform.