LED RECESSED DOWNLIGHTS: ATLANTA, GEORGIA

At the Alston & Bird Law Offices, DOE's Better Buildings Alliance conducted a demonstration of Next Generation LuminairesTM- recognized LED downlight luminaires installed throughout 16 floors of a high-rise office building as part of a larger remodel project. The remodel reduced energy use by 22-37% compared to baseline, primarily because of the lighting system. The LED downlights draw approximately half the wattage of similar CFL downlights, without factoring in potential savings from dimming and controls. (March 2015)

Alston & Bird Law Offices Report

ARCHITECTURAL AND THEATRICAL LIGHTING: GAINESVILLE, FLORIDA

At the University of Florida in Gainesville, the GATEWAY program evaluated LED architectural and theatrical lighting in four academic/performance-related spaces within the Nadine McGuire Theatre + Dance Pavilion. Due to a wise choice of products and luminaire light distributions, the change brought significant quality improvements including improved controllability and color. (July 2014)

University of Florida Report
University of Florida Report Brief

LED RECESSED DOWNLIGHTS: COLUMBUS, OHIO

At the Hilton Columbus Downtown hotel in Ohio, DOE's Better Buildings Alliance conducted a demonstration of Next Generation LuminairesTM-winning downlights installed in all guest rooms and suites prior to the hotel's 2012 opening. After a post-occupancy assessment, the LED downlights not only provided the aesthetic appearance and dimming functionality desired, but also provided 50% energy savings relative to a comparable CFL downlight and enabled the lighting power to be more than 20% below that allowed by code. (June 2014)

Hilton Columbus Downtown Case Study
Hilton Columbus Downtown Report

LED Retrofit Lamps: Washington, DC

In several galleries at the Smithsonian American Art Museum, halogen and incandescent lighting was replaced with LED PAR 30, PAR 38, and MR16 lamps. Although there were performance issues and challenges affecting compatibility with the museum's track fixtures, electricity use reductions were notable—recovering the cost of the LEDs in 16 months of operation through energy savings alone. (June 2012)

Smithsonian American Art Museum Report
Smithsonian American Art Museum Video

LED Retrofit Lamps: Malibu, California

At the J. Paul Getty Museum in Malibu, 12W LED PAR 38 lamps replaced 60W halogen PAR 38 flood lamps on a one-for-one basis for a special photography exhibition. The LED lamps resulted in energy savings approaching 83 percent compared to the traditional halogen system; simple payback was estimated to occur between years two and three. (March 2012)

Getty Museum Report

LED Retrofit Lamps: Eugene, Oregon

In the Jordan Schnitzer Museum of Art in Eugene, 90W PAR38 130V narrow flood lamps used for accent lighting were replaced with 12W LED PAR38 replacement lamps for a special exhibition, and the museum also staged a side-by-side comparison of three different LED PAR38 replacement lamps against their standard halogen lamp. The LED system lighting the exhibition showed a lower present value life-cycle cost, using 14% of the energy and having a life 10 times longer, than the halogen system. (September 2011)

Jordan Schnitzer Museum Report

LED Retrofit Lamps: Portland, Oregon

In the Bonneville Power Administration headquarters building in Portland, 15W and 23W reflectorized compact fluorescent (CFL) track lights used to illuminate artwork were replaced with 12W LED lamps. Although the study did not show rapid payback on the LED installation compared to the CFL products, color quality and power quality improved with the LED lamps, and the narrower light distribution of the LED product more effectively concentrated the lumens on the artwork. (July 2011)

Bonneville Power Administration Report

LED Retrofit Lamps: San Francisco, California

At the InterContinental Hotel in San Francisco, halogen wall-grazing luminaires, track lights, and recessed downlights in the lobby and other common areas were retrofitted with 6W LED MR-16 or 11W PAR30 replacement lamps. The LED lamps resulted in 70% energy savings compared to the halogen lamps, with an estimated payback of a little over one year. (November 2010—Updated to include results of 9000 hour testing, January 2012)

InterContinental Hotel Report

LED Museum Accent Lighting: Chicago, Illinois

At Chicago's Field Museum of Natural History, 32 halogen track luminaires used to light an enclosed gallery exhibit were replaced with an LED system using 26 track fixtures. The LED system resulted in 63% energy savings compared to the halogen system, while achieving a simple payback of roughly 3 years. Because the LED luminaires used do not emit energy in the infrared or ultraviolet regions of the electromagnetic spectrum, they are also expected to be less detrimental to some museum artifacts. (November 2010)

Field Museum Report

LED Freezer Case Lighting: Albertsons Grocery

At an Albertsons Grocery in Eugene, Oregon, upright freezer cases were retrofitted with LED striplights combined with occupancy sensors, and compared against standard fluorescent lighting on the opposite side of the aisle. Calculated payback periods approached five years from estimated energy and maintenance savings for a typical 5-door case. (October 2009)

Freezer Case Report

LED Residential Downlights and Undercabinet Lights: 2008 Eugene Tour of Homes

LED downlights represent one of the most promising applications for SSL technology and significant energy savings. This project studied the installation of LED downlights and undercabinet lights in two "green" showcase homes in Eugene, Oregon. LED downlights are emerging as a viable energy-saving alternative to incandescent and fluorescent downlights. (October 2008)

Eugene Report