In this project, Building Science Corporation evaluated the long-term performance of mini-split heat pumps (MSHPs) in 8 homes during a period of 3 years. The work examined electrical use of MSHPs, distributions of interior temperatures and humidity when using simplified (two-point) heating systems in high-performance housing, and the impact of open-door/closed-door status on temperature distributions.