You are here

Consent Order, Battelle Energy Alliance - NCO-2012-01

January 13, 2012

Issued to Battelle Energy Alliance, LLC, related to the Reactor Coolant Draining Event at the Idaho National Laboratory Advanced Test Reactor

The Office of Health, Safety and Security's Office of Enforcement and Oversight has completed its investigation into the facts and circumstances associated with the inadvertent draining of water from the reactor vessel at the Idaho National Laboratory Advanced Test Reactor {ATR), which occurred during a maintenance outage on June 1, 2011. This occurrence was reported in Noncompliance Tracking System report NTS-ID--BEA-ATR-2011-0003, Low Level in Advanced Test Reactor (ATR) Vessel.